Micro-Embedded Generation (<10kW) Application Home » Micro-Embedded Generation (<10kW) Application Your generation facility must generate electricity from a renewable energy source that is wind, water, solar radiation, or agricultural biomass. Inverter based generating units must not inject DC greater than 0.5% of the full rated output current at the point of connection of the generating units. The generated harmonic levels must not exceed those given in the CAN/CSA-C61000-3-6 Standards. The following information is required for all net-metered generators with total generation of up to 500 kW.Date of Application: DD slash MM slash YYYY Proposed Generation In-Service Date: DD slash MM slash YYYY 1. Project Information:Location: Street Address Address Line 2 City ZIP / Postal Code OwnerName (Company/First, Last): First Last Contact:Mailing Address: Street Address Address Line 2 City Postal Code Telephone (Main):Telephone (Alternate):Fax:Email: Engineering Consultant (Electrical)Name (Company/First, Last): First Last Contact:Mailing Address: Street Address Address Line 2 City Postal Code Telephone (Main):Telephone (Alternate):Fax:Email: 2. Customer Status:Existing Wellington North Power Customer? Yes No Are you a HST registrant? Yes No Please provide your HST registration number:3. Project Size:Total generation capacity (kW):Are all generating units of the same type/size? Yes No 4. Generation Type (check all that apply): Wind Turbine Hydraulic Turbine (water) Photovoltaic (solar) Agricultural Bio-Mass Other Other, Please Specify:5. Customer Owned Step-up Interface Transformer (if applicable):a) Transformer rating (kVA):b) High voltage winding connection: delta star b) Grounding method of star connected high voltage winding neutral: Solid Ungrounded Impedance grounded: Impedance grounded Impedance grounded R:Impedance grounded ohms:c) Low voltage winding connection: delta star c) Grounding method of star connected high voltage winding neutral: Solid Ungrounded Impedance grounded: Impedance grounded Impedance grounded (R):Impedance grounded (ohms):Note: The term ‘High Voltage’ refers to the connection voltage to Wellington North Power Inc.’s distribution system and ‘Low Voltage’ refers to the generator/inverter output voltage.6. Generator/Inverter Information: (For generation facilities installing more than one type of generator, complete section 6 and Appendix A)a) Manufacturer:b) Model Number:c) Number of phase: Single Phase Three Phase d) Nameplate rating (kW);e) Generator/Inverter AC output voltage (Volts):f) Type of inverter: Self-commutated Line-commutated Other Other, please specify:g) Are power factor correction capacitors automatically switched off when generator breaker opens? Yes No h) Is the generator/inverter paralleling equipment and/or design pre-certified and meets anti-islanding test requirements? Yes No i) If answer to above question is Yes, to which standard(s):j) Method of synchronizing the generator/inverter to Wellington North Power Inc.: Manual Automatic k) Maximum inrush current upon generator or inverter connection (linrush/Irated) per unit?7. Grid Interface Controller (if applicable):a) Manufacturer:b) Model No.:8. Single Line Diagram: A Single Line Diagram (SLD) is required with this Application Form. The SLD should include, but should not be limited to: Customer's electrical system showing major electrical equipment, their ratings, location of fault interrupting devices (circuit breakers, fuses) Generating unit(s) and their connection arrangement to Customer's electrical system Protection, metering and proposed tripping schemes Isolating/disconnecting device for the isolation of the generating unit(s) from Wellington North Power Inc.'s system; suitably rated, accessible (to Wellington North Power Inc. personnel), visible, gang operated, lockable. If applicable, information on customer owned step-up interface transformer: ratings, winding connections, grounding arrangements.Please e-mail your single line diagram to generation@wellingtonnorthpower.com quoting the SLD drawing number. SLD Drawing Number:9. Location & Site Plan (only required for generators greater than 50 kW): Provide a site plan (sketch) showing electric service entrance, step-down transformer, generator(s)/inverter(s) location, existing/new switchgear, location of the isolating/disconnecting device (for Wellington North Power Inc. use), adjoining street name, and street address. Please e-mail your location & site plan to generation@wellingtonnorthpower.com quoting the sketch number.Drawing/Sketch No. :Note: Additional information may be required. Wellington North Power Inc. will inform you of what additional information is required.Applicant Digital Signature: I agree.Please accept this digital signature as my authority to activate this agreement.Date: DD slash MM slash YYYY